0102030405
Yuken PV2R Series Vane Pumps: Low Noise Performance from Leading China Suppliers and Factory for Precision Manufacturing
Single Pumps
| Model | Displacement (mL/r) |
Max.pressure(MPa) | Speed(r/min) | Input power (kW) |
|||
| Special oil | Antiwear oil | Common oil | Min. | Max. | |||
| PV2R1-4 | 4.3 | 21 | 17.5 | 16 | 750 | 1800 | 2.1 |
| PV2R1-6 | 6.5 | 3.2 | |||||
| PV2R1-8 | 8.5 | 4.5 | |||||
| PV2R1-10 | 10.8 | 5.4 | |||||
| PV2R1-12 | 12.8 | 6.1 | |||||
| PV2R1-14 | 14.5 | 6.9 | |||||
| PV2R1-17 | 16.2 | 7.9 | |||||
| PV2R1-19 | 20.1 | 9.6 | |||||
| PV2R1-23 | 22.5 | 10.5 | |||||
| PV2R1-25 | 25.3 | 12.5 | |||||
| PV2R1-28 | 29.6 | 14.0 | |||||
| PV2R1-31 | 32.3 | 16 | 16 | 15.5 | |||
| PV2R2-26 | 25.3 | 21 | 17.5 | 14 | 600 | 1800 | 11.7 |
| PV2R2-33 | 32.3 | 15.5 | |||||
| PV2R2-41 | 39.8 | 18.9 | |||||
| PV2R2-47 | 49.8 | 23.2 | |||||
| PV2R2-53 | 51.5 | 24 | |||||
| PV2R2-59 | 55.8 | 24.9 | |||||
| PV2R2-65 | 63.7 | 29.4 | |||||
| PV2R2-70 | 70.3 | 16 | 1200 | 31.6 | |||
| PV2R2-79 | 78.1 | 35.7 | |||||
| PV2R2-85 | 82.7 | 37.5 | |||||
| PV2R3-52 | 51.5 | 21 | 17.5 | 14 | 600 | 1800 | 23.2 |
| PV2R3-60 | 63.7 | 29.4 | |||||
| PV2R3-66 | 66.6 | 34.2 | |||||
| PV2R3-76 | 75.5 | 37.7 | |||||
| PV2R3-94 | 89.5 | 41.2 | |||||
| PV2R3-116 | 118 | 16 | 16 | 50 | |||
| PV2R3-125 | 122.2 | 1200 | 59.9 | ||||
| PV2R3-136 | 136 | 66.7 | |||||
|
Note:
1. When pressure of pumps exceeds 16MPa, with displacement of "4" "6" "8", speeds should be more than 1450r/min. 2. Reduce the negative pressure of the inlet when the single pumps or double pumps with large displacement at high speed. 3. In use of synthetic hydraulic fluids and water containing hydraulic fluids, limit the max speed at 1200r/min. 4. Speed at 1000r/min is suggested on occasions with lower noise strictly required. 5. Noisiness is available in working conditions of 14MPa and 1200r/min. 6. Input power is available in working conditions of 16MPa and 1500r/min. |
|||||||
Double Pumps
Installation Dimensions
| Shaft type | A | B | C | D | F | G | H |
| F1 | 178.5 | 69.5 | 44.5 | 36 | 19.05 | 21.24 | 4.76 |
| F | 184 | 75 | 50 | 41 | 15.88 | 17.68 | 3.97 |
| Shaft type | F | G |
| F1 | 25.4 | 28.18 |
| F | 22.23 | 25.01 |
| Shaft type | A | B | C | D | E | F | G |
| F1 | 326 | 95 | 67 | 55 | 40 | 25.4 | 28.18 |
| F | 318 | 87 | 59 | 47 | 32 | 22.23 | 25.01 |
Port flange kits
Double Pumps
| Flange model |
Corresponding pipe specifications |
Dimensions mm | O Ring GB3452.1- 2005 |
PV2R Series | ||||||||||||
| C | D | E | F | H | J | L | N | Q | T | socket head screw |
Dimensions K |
Corresponding oil pump interface |
||||
| F04-A | 1/2" | 40 | 54 | 17.5 | 38.1 | 9.0 | 27 | Rc1/2" | 一 | 一 | 13 | 21.2x2.65 | M8x30mm | 12.5 | PV2R1 outlet,PV2R21, PV2R31 outlet of cover end pump |
|
| F04-B | 一 | 11 | 22.5 | |||||||||||||
| F06-A | 3/4" | 50.5 | 65.5 | 22.2 | 47.6 | 11.0 | 28 | Rc3/4" | 一 | 一 | 19 | 30x3.55 | M10x30mm | 12.5 | PV2R2 outlet,PV2R21 outlet of shaft end pump PV2R32 outlet of cover end pump |
|
| F06-B | 一 | 12 | 28.5 | |||||||||||||
| F08-A | 1" | 56 | 71 | 26.2 | 52.4 | 11.0 | 30 | Rc1" | 一 | 26 | 34.5×3.55 | M10x35mm | 17.0 | PV2R1 inlet port | ||
| F08-B | 14 | 34.5 | ||||||||||||||
| F10-A | 1-1/4" | 64.5 | 79.5 | 30.2 | 58.7 | 12.0 | 32 | Rc1-1/4” | 一 | - | 32 | 40x3.55 | M10x40mm | 19 | PV2R2 inlet port,PV2R3 outlet, PV2R31, PV2R32 outlet of shaft end pump | |
| F10-B | - | 16 | 43.0 | |||||||||||||
| F12-A | 1-1/2" | 71 | 94 | 35.7 | 69.9 | 13.8 | 37 | Rc1-1/2" | 一 | 一 | 38 | 50x3.55 | - | - | - | |
| F12-B | 18 | 49.1 | ||||||||||||||
| F16-A | 2" | 87.5 | 103 | 42.9 | 77.8 | 13.8 | 38 | Rc2" | - | - | 51 | 65x3.55 | M12x45mm | 17.5 | PV2R3、PV2R21 inlet | |
| F16-B | 一 | 20 | 61.0 | |||||||||||||
| F20-A | 2-1/2" | 96 | 115 | 50.8 | 88.9 | 13.8 | 42 | Rc2-1/2" | 63 | 75x3.55 | - | 一 | ||||
| F20-B | - | 22 | 77.1 | |||||||||||||
| F24-A | 3" | 123 | 136 | 61.9 | 106.4 | 17.0 | 45 | Rc3" | - | 76 | 85x3.55 | M16x45mm | 16.5 | PV2R31、PV2R32 inlet | ||
| F24-B | 一 | 25 | 90.0 | |||||||||||||
| F28-A | 3-1/2" | 135 | 153 | 69.9 | 120.7 | 17.5 | 46 | Rc3-1/2" | 一 | 89 | 100x3.55 | 一 | ||||
| F28-B | 20 | 102.8 | ||||||||||||||
| F32-A F32-B |
4" | 145 | 162 | 77.8 | 130.2 | 17.0 | 5040 | Rc4" | 一 | 一 | 102 | 115x3.55 | 一 | |||
| 一 | 28 | 115.5 | ||||||||||||||
| Flange model |
V、V Q、SOP、T6 Series | |||||||||||||||
| socket head screw | Dimensions K |
Corresponding oil pump interface | ||||||||||||||
| F04-A | 一 | 一 | 一 | |||||||||||||
| F04-B | ||||||||||||||||
| F06-A | 3/8"-16UNCx1.5"(38.1mm) | 20.6 | 20V(Q)、SQP1 outlet,2520V(Q)、3520V(Q)、4520V(Q)、SQP21、SQP31、SQP41、T6CC(01、11 oil port dimensions)、T6DCC(01 oil port dimensions)、T6DDCS(01 oil port dimensions)、T6EDC(S)(01 oil port dimensions) outlet of cover end pump | |||||||||||||
| F06-B | ||||||||||||||||
| F08-A | 3/8"-16UNCx1.5"(38.1mm) | 20.1 | 25V(Q)、SQP2、T6C outlet port,2520V(Q)、SQP21、T6CC outlet of shaft end pump, 3525V(Q)、4525V(Q)、SQP32、SQP42、T6CC(00、10 oil port dimensions)、T6EC、T6DCC(00 oil port dimensions)、T6DDCS(00 oil port dimensions)、T6EDC(S)(00 oil port dimensions) outlet of cover end pump、T6DCC outlet of middle pump | |||||||||||||
| F08-B | ||||||||||||||||
| F10-A | 7/16"-14UNCx1.575" (40mm) |
19.0 | SQP1 inlet,35V(Q)、SQP3、T6D outlet,3520V(Q)、3525V(Q)、SQP31、SQP32、T6DC、T6DCC、T6DDCS outlet of shaft end pump,4535V(Q)、SQP43、T6ED outlet of cover end pump,T6DDCS、T6EDC(S) outlet of middle pump | |||||||||||||
| F10-B | ||||||||||||||||
| F12-A | 1/2"-13UNCx1.75"(44.5mm) | 19.0 | 20V(Q)、25V(Q)、SQP2、T6C inlet,45V(Q)、SQP4、T6E outlet, 4535V(Q)、SQP43、T6EC、T6ED、T6EDC(S) outlet of shaft end pump | |||||||||||||
| F12-B | ||||||||||||||||
| F16-A | 1/2"-13UNCx1.75"(44.5mm) | 17.0 | 35V(Q)、SQP3、T6D inlet | |||||||||||||
| F16-B | ||||||||||||||||
| F20-A | 1/2“-13UNCx1.75”(44.5mm) | 16.5 | 2520V(Q)、SQP21、T6CC(10、11/oil port dimensions) inlet | |||||||||||||
| F20-B | ||||||||||||||||
| F24-A | 5/8"-11UNCx2"(50.8mm) | 22.3 | 45V(Q)、SQP4、T6E inlet,3520V(Q)、3525V(Q)、SQP31、SQP32、T6CC (00、01/oil port dimensions)、T6DC inlet | |||||||||||||
| F24-B | ||||||||||||||||
| F28-A | 5/8"-11UNCx2"(50.8mm) | 22.3 | 4520V(Q)、4525V(Q)、SQP41、SQP42、T6EC inlet | |||||||||||||
| F28-B | ||||||||||||||||
| F32-A | 5/8"-11UNCx2"(50.8mm) | 19.3 | 4535V(Q)、SQP43、T6ED、T6DCC、T6DDCS、T6EDC(S) inlet | |||||||||||||
| F32-B | 5/8"-11UNCx1.75"(44.5mm) | 23.0 | ||||||||||||||
Frequently Asked Questions (FAQ)
What are the main features of the Yuken PV2R Series Vane Pumps?
The Yuken PV2R series features high-pressure performance, low noise operation, high efficiency, and a compact design, making them ideal for various industrial hydraulic systems.
What is the maximum pressure rating for the PV2R1, PV2R2, and PV2R3 single pumps?
Under standard conditions using special or antiwear hydraulic oil, the maximum pressure can reach up to 21 MPa (210 bar) depending on the specific model.
Can the Yuken PV2R Series pumps operate with synthetic hydraulic fluids?
Yes, they can operate with synthetic hydraulic fluids and water-containing fluids, but the maximum speed should be limited to 1200 r/min.
What is the recommended speed for low-noise applications?
For applications requiring strictly lower noise levels, a speed of 1000 r/min is suggested.
How do I select the right shaft type (F or F1) for installation?
Refer to the installation dimensions tables and diagrams. The shaft types differ in key dimensions such as diameter (F) and length (D). Ensure alignment with your motor coupling specifications.
What is the benefit of using double pumps instead of single pumps?
Double pumps combine two pumping cartridges in a single housing driven by a single shaft, allowing you to run two separate hydraulic circuits or achieve higher flow rates efficiently.