Leave Your Message

VG22D Quality Replacement for Rexroth Pgh-3X Hydraulic Gear Pump Vg Series for Injection Molding Machines

Introduction double pump

The double pump is composed of two single pumps assembled in series, with one oil inlet and independent oil outlet, according to the series of two pumps, can be obtained displacement: VG10D series, VG11D series, VG21D series, VG22D series.

    Product Features

    The front and rear oil pumps adopt floating flower-splined coupling structure, with a unique grease formula to ensure stable performance, long life and low noise of the oil pump;
    The maximum displacement can be extended to 320CC, which provides enough choice space for motor and driver selection and model selection;
    The direction of oil outlet and suction outlet of oil pump is flexible and easy to install;
    Any displacement combination, to meet the needs of different working conditions.
    • Quality Replacement for Rexroth Pgh-3X Hydraulic Gear Pump Vg Series for Injection Molding Machines VG11D (1)
    • VG11D Quality Replacement for Rexroth Pgh-3X Hydraulic Gear Pump Vg Series for Injection Molding Machines
    • VG21D Quality Replacement for Rexroth Pgh-3X Hydraulic Gear Pump Vg Series for Injection Molding Machines
    • VG22D Quality Replacement for Rexroth Pgh-3X Hydraulic Gear Pump Vg Series for Injection Molding Machines

    Model Designation

    VG11D

    -63

    -40

    R

    E

    W

    -A1

    Series

    ml/r
    Flow code of shaft
    end pump

    ml/r
    Flow code of cover
    end pump

    Rotation
    direction

    Shaft type

    Sealing material

    Design number

    VG10D

    25、32、40、50、63

    8、10、13、16、
    20、25

    Viewed from
    shaft end of
    pump

    R=Right hand for
    clockwise

    L-Left hand for
    counter-
    clockwise

    E=Straight key
    shaft

    R=SAE Spline shaft

    W=(Buna)
    NBR

    V=FKM

    A1

    VG11D

    25、32、40、50、63

    25、32、40、50、63

    VG21D

    80、100、125、
    145、160

    25、32、40、50、63

    VG22D

    80、100、125、
    145、160

    80、100、125、
    145、160

    Installation-Dimensions

    Front
    pump

    L1

    L2

    Rear pump

    80

    100

    125

    145

    160

    L3

    L4

    L3

    L4

    L3

    L4

    L3

    L4

    L3

    L4

    80

    109.5

    238.5

    233

    437

     

     

     

     

     

     

     

     

    100

    114

    247.5

    237.5

    446

    242

    455

     

     

     

     

     

     

    125

    120

    259.5

    243.5

    458

    248

    467

    254

    479

     

     

     

     

    145

    124.8

    269

    248.3

    467.5

    252.8

    476.5

    258.8

    488.5

    263.5

    498

     

     

    160

    129

    277.5

    252.5

    476

    257

    485

    263

    497

    267.8

    506.5

    272

    515

    Installation-Dimensions

    Front
    pump

    L1

    L2

    Rear pump

    25

    32

    40

    50

    63

    L3

    L4

    L3

    L4

    L3

    L4

    L3

    L4

    L3

    L4

    80

    110

    231

    205

    380

    208

    387

    211.5

    394

    216.5

    404

    223.5

    418

    100

    114.0

    240

    209.0

    389

    213

    396

    216

    403

    221

    413

    228

    427

    125

    120

    252

    215

    401

    218.5

    408

    222

    415

    227

    425

    234

    439

    145

    125

    262

    220

    411

    223.3

    418

    227

    425

    232

    435

    238.8

    448.5

    160

    129

    270

    224

    419

    227.5

    426

    231

    433

    236

    443

    243

    457

    Installation-Dimensions

    Front
    pump

    L1

    L2

    Rear pump

    25

    32

    40

    50

    63

    L3

    L4

    L3

    L4

    L3

    L4

    L3

    L4

    L3

    L4

    25

    73

    161

    161

    300

     

     

     

     

     

     

     

     

    32

    76.5

    168

    164.5

    307

    168

    314

     

     

     

     

     

     

    40

    80

    175

    168

    314

    171.5

    321

    175

    328

     

     

     

     

    50

    85

    185

    173

    324

    176.5

    331

    180

    338

    185

    348

     

     

    63

    92

    199

    180

    338

    183.5

    345

    187

    352

    192

    362

    199

    376

    Installation-Dimensions

    Front
    pump

    L1

    L2

    Rear pump

    08

    10

    13

    16

    20

    25

    L3

    L4

    L3

    L4

    L3

    L4

    L3

    L4

    L3

    L4

    L3

    L4

    25

    73

    153.5

    138.5

    264.5

    140.5

    268.5

    143.8

    275

    146.5

    280.5

    150.5

    288.5

    154.5

    296.5

    32

    76.5

    160.5

    142

    271.5

    144

    275.5

    147.3

    282

    150

    287.5

    154

    295.5

    158

    303.5

    40

    80

    167.5

    145.5

    278.5

    147.5

    282.5

    150.8

    289

    153.5

    294.5

    157.5

    302.5

    161.5

    310.5

    50

    85

    177.5

    150.5

    288.5

    152.5

    292.5

    155.8

    299

    158.5

    304.5

    162.5

    312.5

    166.5

    320.5

    63

    92

    191.5

    157.5

    302.5

    159.5

    306.5

    162.8

    313

    165.5

    318.5

    169.5

    326.5

    173.5

    334.5

    FAQ

    Q1: Can the two pump sections of the VG double pump have different displacements (flow rates)?
    A: Yes, absolutely. A key feature of our VG double pump series is the ability to combine two cartridge assemblies (pump sections) with different displacements. This flexibility allows you to create a compact, custom flow solution perfect for applications like:
    Plastic Injection Molding Machines: High flow for fast mold closing, lower flow for high-pressure injection.
    Machine Tools: High flow for rapid traverse, lower flow for precise feed motion.
    Q2: How is the pressure rating handled for each section of the double pump?
    A: Each pump section within the VG double pump has its own independent outlet port and is rated for its own maximum operating pressure (as listed in the technical specifications). This means:
    ● Circuit A can operate at its maximum rated pressure (e.g., 250 bar).
    ● Circuit B simultaneously operates at a different pressure (e.g., 150 bar), as determined by the load in each circuit and their respective pressure relief valves.
    ● The common shaft and bearings are designed to handle the combined loads from both sections.
    Q3: If one pump section fails, does the entire double pump unit need to be replaced?
    A: No, in most cases, the entire unit does not need to be replaced. The modular design of the VG double pump allows for individual repair or replacement of the faulty cartridge assembly (pump section). This serviceability feature:
    Reduces Downtime: You can service only the failed section.
    Lowers Lifecycle Cost: It is more economical than replacing the complete pump assembly.
    We provide comprehensive support, including detailed documentation and availability of repair kits and individual cartridges to minimize your maintenance overhead.