0102030405
Rexroth LA10V31 Series Hydraulic Piston Pump - High Efficiency China Suppliers and Factory Solutions
Model Designation
| LA10VS | Model variable pump, swashplate design Rated pressure 280bar Peak pressure 350bar |
| O | Mode of operation pump, open circuit |
| 28 | Displacement: 18, 28, 45, 71, 100, 140(ml/r) |
| DR | Mode of operation | 18 | 28 | 45 | 71 | 100 | 140 |
| DG | √ | √ | √ | √ | √ | √ | |
| DR | √ | √ | √ | √ | √ | √ | |
| DRG | √ | √ | √ | √ | √ | √ | |
| DFR | √ | √ | √ | √ | √ | √ | |
| DFR1 | √ | √ | √ | √ | √ | √ | |
| DFLR | √ | √ | √ | √ | √ |
| 31 | Product series: 31 series |
| R | Direction of Rotation R--Clockwise L--Anti-clockwise |
| P | Seals P--Perbunan V--Viton |
| S | Shaft end | 18 | 28 | 45 | 71 | 100 | 140 |
| P--Metric parallel with key | √ | √ | √ | √ | √ | √ | |
| S--SAE SAE splined | √ | √ | √ | √ | √ | √ | |
| R--SAE SAE splined (higher through drive torque) | √ | √ | √ | √ | |||
| K--SAE SAE parallel with key | √ | √ | √ | √ | √ | √ | |
| U--SAE SAE splined reduced dia, NOT for through drive | √ | √ | √ | ||||
| W--SAE Similar to shaft "u", higher input torque, not for through drive | √ | √ |
| C | Mount flange | 18 | 28 | 45 | 71 | 100 | 140 |
| A-ISO ISO 2-hole | √ | √ | √ | √ | √ | ||
| C-SAE SAE 2-hole | √ | √ | √ | √ | √ | ||
| B-ISO ISO 4-hole | √ | ||||||
| D-SAE SAE 4-hole | √ |
| 62 | Port of service lines | 18 | 28 | 45 | 71 | 100 | 140 |
| 11--SAE flange rear, fixing thread metric | √ | √ | √ | √ | √ | √ | |
| 61--SAE flange rear, fixing thread NUC | √ | √ | √ | √ | √ | √ | |
| 12--SAE flange on opposite side, fixing thread metric | √ | √ | √ | √ | |||
| 62--SAE flange on opposite NUC | √ | √ | √ | √ | √ | √ | |
| 41(91)--SAE flange rear, fixing thread metric (NUC) | √ | √ | √ | ||||
| 42(92)--SAE flange on opposite side, fixing thread metric (NUC) | √ | √ |
| N00 | With through drive to accept an axial piston pump or gear pump | 18 | 28 | 45 | 71 | 100 | 140 | |
| Without through drive | √ | √ | √ | √ | √ | √ | N00 |
Technical Data
| Operating pressure range-inlet | Operating pressure range-inlet | ||
| Absolute pressure at port S | Pressure at port B | ||
| Pabs min | 0.8 bar | Nominal pressure | 280 bar |
| Pabs max | 30 bar | Peak pressure Pmax | 350 bar |
| Applications with intermittent operating pressures up to 315 bar at 10% duty are permissible. | |||
| Size | 18 | 28 | 45 | 71 | 100 | 140 | |||
| Displacement | Vg max | cm³ | 18 | 28 | 45 | 71 | 100 | 140 | |
| Max. speed | n max | rpm | 3300 | 3000 | 2600 | 2200 | 2000 | 1800 | |
| Max. output flow | In n max | qv | L/min | 59.4 | 84 | 117 | 156 | 200 | 252 |
| In 1500rpm | qv | L/min | 27 | 42 | 68 | 107 | 150 | 210 | |
| Max. power (△P=280MPa) | In n max | P max | kW | 27.7 | 39 | 55 | 73 | 93 | 118 |
| In 1500rpm | P max | kW | 12.6 | 20 | 32 | 50 | 70 | 98 | |
| Max. torque (△P=280MPa) | In Vg max | T max | N.m | 80.1 | 125 | 200 | 316 | 445 | 623 |
| Weight (approximately) | m | kg | 12 | 15 | 21 | 33 | 45 | 60 | |
Operation Mode
DG-Two-point control, direct operated
DR--Pressure control
In the control range of the pump, the pressure in the hydraulic system is kept constant. Therefore, the pump only provides the hydraulic oil required for the actuator. Pressure can be set in the control valve.
DRG-- Remote pressure control
The remote control can be realized by connecting an overflow valve with the oil port X. However, the overflow valve is not included in the DRG control of the supply range. DRG control valve core standard pressure is located in 20bar, the pressure difference generated 1.5L/min control flow. For other settings, please use the text description. We recommend using the flowing one as a separate relief valve: according to the RC25402 of DBD6 (hydraulic), or by RC29166 DBETR-SO381, P with throttle hole whose diameter is 0.8(control). The maximum length of the pipe shall not exceed 2m.
DFR/DFR1-- Pressure/flow control
In addition to the pressure control function, but also through the differential pressure (such as the throttle valve or valve on the pressure difference) to regulate the flow of the pump flow. Pump to provide the oil needed for the actuator. In the DFR1 type, the throttle hole between the oil port X and the fuel tank is blocked.
DFLR-- Pressure/flow/power control
In order to obtain a constant driving torque in the case of working pressure change, by changing the angle of the axial piston element, thus changing the output flow, so that the product of flow and pressure remain constant. Flow control can only be in the constant power control curve.
Dimension & Size
Frequently Asked Questions (FAQ)
Q1: What are the rated and peak pressures for the LA10VS series pump?
The LA10VS variable displacement pump has a rated operating pressure of 280 bar and can handle a peak pressure of up to 350 bar.
Q2: What displacement sizes are available in this product line?
The series offers displacements of 18, 28, 45, 71, 100, and 140 ml/r, allowing you to select the exact model configuration needed for your system requirements.
Q3: How does the DR pressure control mode operate?
In DR mode, the pressure within the hydraulic system is maintained at a constant level. The pump only supplies the specific volume of hydraulic oil demanded by the actuator, which helps optimize energy usage.
Q4: What is the main difference between DFR and DFR1 control modes?
Both modes regulate the flow using differential pressure (such as across a throttle valve). However, in the DFR1 model, the throttle hole located between the oil port X and the fuel tank is blocked.
Q5: Does the pump support through-drive configurations for auxiliary pumps?
Yes, models designated with the "N00" code feature a through-drive system designed to accept and drive an additional axial piston pump or gear pump.
Q6: What mounting flange options are available for the LA10VS series?
Depending on the frame size, the pump supports ISO 2-hole, SAE 2-hole, ISO 4-hole, and SAE 4-hole mounting configurations to match standard hydraulic system designs.