LA10VSO 32 Series Axial Piston Variable Pump - Top Choice from China Suppliers and Factory

Discover top-quality products manufactured in China from trusted suppliers and factories. Our extensive range showcases the finest craftsmanship and innovation that Chinese suppliers are renowned for. With a commitment to excellence, our factory partners ensure that each product meets the highest standards of quality and performance. Elevate your business with reliable products sourced directly from China's leading suppliers, and experience the difference that factory-direct pricing and superior manufacturing can make. Explore our collection today and join the global marketplace with confidence!

    Features

    • Variable displacement pump with axial piston rotary group of swash-plate design for hydro-static drives in open circuit.
    • Flow is proportional to the drive speed and displacement.
    • The flow can be infinitely varied by adjusting the swash-plate angle.
    • Hydro-statically unloaded cradle bearing
    • Port for measurement sensor on the high-pressure port
    • Low noise level
    • Low pressure pulsation
    • High efficiency
    • High resistance to cavitation, suction pressure drops and housing pressure peaks
    • Universal through drive

    Order model/standard product

    01

    02

    03

    04

    05

    06

    07

    08

    09

    10

    11

    12

    13

    LA10VS

    O

       

    /

    32

     

    -

    V

     

    B

           
    Axial piston unit

    01

    Swash-plate design, variable, nominal pressure 280 bar, maximum pressure 350 bar

    LA10VS

    Operating mode

    02

    Pump, open circuit

    O

    Size (NG)

    03

    Geometric displacement

    045

    071

    100

    140

    Control device                                    045   071   100   140

    04

    Two-point control, directly operated

    ·

    ·

    ·

    ·

    DG

    Pressure controller     hydraulic

    ·

    ·

    ·

    ·

    DR

    With flow control hydraulic X-T open

    ·

    ·

    ·

    ·

    DRF

    X-T plugged

    ·

    ·

    ·

    ·

    DRS

    Pressure cut-off hydraulic Remotely operated

    ·

    ·

    ·

    ·

    DRG

    Electric Negative control U=12V

    ·

    ·

    ·

    ·

    ED71

    U=24V

    ·

    ·

    ·

    ·

    ED72

    Electric Positive control U=12V

    ·

    ·

    ·

    ·

     
    U=24V

    ·

    ·

    ·

    ·

     
    Power control with pressure cut-off hydraulic Control begin To 50 bar

    ·

    ·

    ·

    ·

    LA5D

    From 51 to 90 bar

    ·

    ·

    ·

    ·

    LA6D

    From 91 to 160 bar

    ·

    ·

    ·

    ·

    LA7D

    From 160 to 240 bar

    ·

    ·

    ·

    ·

    LA8D

    Above 240 bar

    ·

    ·

    ·

    ·

    LA9D

    Remotely operated hydraulic Control begin See LA.D

    ·

    ·

    ·

    ·

    LA.DG

    Flow control, X-T plugged hydraulic Control begin See LA.D

    ·

    ·

    ·

    ·

    LA.DS

    Electrically overridable (negative control) See LA.D

    ·

    ·

    ·

    ·

    LA.S

    Series
    05 Series 3, index 2

    32

    Direction of rotation

    06

    Viewed on drive shaft clockwise

    R

    Counter-clockwise

    L

    Seal

    07

    FKM (fluor-caoutchouc)

    V

    Drive shafts

    08

    Parallel keyed shaft ISO 3019-1(SAE J744)limited suitability for through drive

    ·

    ·

    ·

    ·

    ·

    P

    Splined shaft Standard shaft

    ·

    ·

    ·

    ·

    ·

    S

    ANSI B92.1a Similar to shaft “S” however for higher input torque

    ·

    ·

    -

    -

    -

    R

    Mounting flange

    09

    ISO 3019-2; 4 hole

    B

    The following must be taken into account during project planning: Excessive current levels (I>1200 mA at 12V or I>600mA at 24 V) to the ER solenoid can result in undesired pressure increases which can lead to pump or system damage.

    Therefore:
    -Use Imax current limiter solenoids.
    -A sandwich plate pressure reducing valve can be used to protect the pump in the event of overflow.
    Service line ports                              045   071   100  140

    10

    SAE flange ports at top, at bottom, on opposite side, UNF fastening thread with universal through drive Without pulsation damping

    ·

    ·

    ·

    ·

    22U

    With pulsation damping, not for high-speed

    ·

    ·

    ·

    ·

    32U

    Through drives (for fitting options)
    Through-drives
    Rotary group version

    12

    Standard rotary group(noise-optimized for n=1500/1800 rpm)

    ·

    ·

    ·

    ·

    E

    High-speed(with port plate version 72U only)

    ·

    ·

    ·

    ·

    S

    Connector for solenoids

    13

    Without connector(without solenoid, with hydraulic control only, without code)
    HIRSCHMANN connector-without suppressor diode

    H

    Factory Wholesale Rexroth LA10V53 Hydraulic Axial Piston Pumps detail

    Installation instructions

    General
    The axial piston unit must be filled with hydraulic fluid and air bled during commissioning and operation. This must also be considered with a long-term standstill.

    Particularly with the “drive shaft up/down” installation position, filling and air bleeding must be carried out completely as there is, for example, a danger of dry running. The case drain fluid in the pump housing must be discharged to the reservoir via the highest available drain port (L, L₁). For combinations of multiple units, the case drain fluid must be drained off at each pump. We recommend laying separate drain lines. If this is not possible, a shared drain line may need to be laid. If a shared drain line is used for this purpose, make sure that the case pressure in each pump is not exceeded. In the event of pressure differences at the drain ports of the units, the shared drain line must be changed so that the minimum permissible case pressure of all connected units is not exceeded in any situation. If this is not possible, separate drain lines must be laid if necessary.

    To achieve favorable noise values, decouple all connecting lines using elastic elements and avoid above-reservoir installation.

    In all operating conditions, the suction line and drain line must flow into the reservoir below the minimum fluid level. The permissible suction height hs results from the overall loss of pressure. However, it must not be higher than hs max=31.50 in (800 mm). The minimum suction pressure at port S (see the technical data on page 64) must not be fallen short of during operation and at cold starting either. When designing the reservoir, ensure that there is sufficient distance between the suction line and the drain line. This prevents the heated, return flow from being drawn directly back into the suction line.
    Installation instructions01
    Installation position
    See the following examples 1 to 9. Further installation positions are available upon request. Recommended installation position: 1 and 3
    Below-reservoir installation (standard)
    Below-reservoir installation is when the axial piston unit is installed outside of the reservoir below the minimum fluid level.
    Installation instructions02
    Note
    Port F is part of the external piping and must be provided by the customer to make filling and air bleeding easier.

    Above-reservoir installation
    Above-reservoir installation means the axial piston unit is installed above the minimum fluid level of the reservoir. To prevent the axial piston unit from draining in position 5, the height difference hES min must be at least 0.98 in (25 mm). Observe the maximum permissible suction height hs max=31.50 in (800 mm).
    Installation instructions03
    A check valve in the case drain line is only permissible in individual cases. Consult us for approval.
    1) Because complete air bleeding and filling are not possible in this position, the pump should be air bled and filled in a horizontal position before installation.
    Inside-reservoir installation
    Reservoir installation is when the axial piston unit is installed in the reservoir below the minimum fluid level. The axial piston unit is completely below the hydraulic fluid.

    If the minimum fluid level is equal to or below the upper edge of the pump, see chapter “Above-reservoir installation”.

    Axial piston units with electrical components (e.g., electric control, sensors) may not be installed in a reservoir below the fluid level.
    Installation instructions04
    Assembly note
    Due to the compact design of the casing, socket-head screws with a hexagon socket must be used to attach the axial piston pump. Please observe the maximum permissible surface pressure according to VDI2230.

    Apart from this, you should take into account the information regarding tightening torques in the operating instruction.

    Project planning notes

    • The LA10VSO axial piston variable pump is intended to be used in open circuit.
    • Project planning, installation and commissioning of the axial piston units requires the involvement of skilled personnel.
    • Before using the axial piston unit, please read the corresponding instruction manual completely and thoroughly. If necessary, this can be requested from us.
    • Before finalizing your design, request a binding installation drawing.
    • The specified data and notes contained herein must be observed.
    • Depending on the operating conditions of the axial piston unit (working pressure, fluid temperature), the characteristic curve may shift. The characteristic curve may also shift due to the dither frequency or control electronics.
    • Preservation: Our axial piston units are supplied as standard with preservation protection for a maximum of 12 months. The preservation periods apply under optimal storage conditions, details of which can be found in the data sheet 90312 or the instruction manual.
    • Not all versions of the product are approved for use in a safety function according to ISO 13849. Please consult the proper contact us if you require reliability parameters (e.g. MTTFd) for functional safety.
    • Depending on the type of control used, electromagnetic effects can be produced when using solenoids. Applying a direct voltage signal (DC) to solenoids does not create electromagnetic interference (EMI) nor is the solenoid affected by EMI. Electromagnetic interference (EMI) potential exists when operating and controlling a solenoid with a modulated direct voltage signal (e.g. PWM signal). Appropriate testing and measures should be taken by the machine manufacturer to ensure other components or operators (e.g. with pacemaker) are not affected by this potential.
    • Pressure controllers are not safeguards against pressure overload. Be sure to add a pressure relief valve to the hydraulic system.
    • For drives that are operated for a long period of time with constant rotational speed, the natural frequency of the hydraulic system can be stimulated by the excitation frequency of the pump (rotational speed frequency × 9). This can be prevented with suitably designed hydraulic lines.
    • Please note the details regarding the tightening torques of port threads and other threaded joints in the instruction manual.
    • The ports and fastening threads are designed for the Pmax permissible pressures of the respective ports, see the connection tables. The machine or system manufacturer must ensure that the connecting elements and lines correspond to the specified application conditions (pressure, flow, hydraulic fluid, temperature) with the necessary safety factors.
    • The working ports and function ports are only intended to accommodate hydraulic lines.

    Frequently Asked Questions (FAQ)

    Q1: What are the main features of the LA10VS variable displacement pump?
    A1: The LA10VS features an axial piston rotary group in a swash-plate design for open circuit hydrostatic drives. It provides proportional flow to drive speed and displacement, infinitely variable flow via swash-plate adjustments, low noise levels, low pressure pulsation, high efficiency, and high resistance to cavitation.
    Q2: What current limits should be observed for the ER solenoid?
    A2: Excessive current levels (greater than 1200 mA at 12V or 600 mA at 24V) to the ER solenoid can cause undesired pressure increases, potentially damaging the pump or system. You should use Imax current limiter solenoids.
    Q3: How should the axial piston unit be prepared during commissioning?
    A3: The unit must be completely filled with hydraulic fluid and air bled during commissioning and operation, particularly in the "drive shaft up/down" position, to prevent dry running. Case drain fluid must be discharged to the reservoir via the highest available drain port.
    Q4: What is the difference between below-reservoir and above-reservoir installation?
    A4: Below-reservoir installation places the pump outside the reservoir below the minimum fluid level. Above-reservoir installation places the pump above the minimum fluid level, requiring a minimum height difference (hES min) of 0.98 in (25 mm) to prevent draining, and a maximum suction height (hs max) of 31.50 in (800 mm).
    Q5: Do pressure controllers act as safeguards against pressure overload?
    A5: No, pressure controllers are not safeguards against pressure overload. You must integrate a separate pressure relief valve into the hydraulic system to protect against overload.