Leave Your Message

High-Performance VQ Series Vane Pump Cartridges from China Factory - Reliable Suppliers for Demanding Applications

The VQ Series High-Performance Vane Pump Cartridges are meticulously designed for demanding applications, making them the ideal choice for industries in need of reliable and efficient pump systems. As a leading manufacturer in China, we pride ourselves on delivering top-quality products that meet rigorous standards. Our factory utilizes advanced technology and expertise to produce vane pump cartridges that offer outstanding durability and performance. Partner with trusted suppliers to ensure you receive the best in high-performance pumping solutions. Elevate your operations with the VQ Series from our factory in China today!

    Model Designation

    Vq Series Cartridge
    (F3-) PC- 25VQ 19 R 10
    Note Cartridge mark Series Displacement Rotation Design number
    No-marking:

    Petroleum series oil emulsification fluid

    water glycol-fluid F3:

    phosphate ester fluid
    PC- Cartridge kit of single pump double pump shaft end

    PCT-Cartridge kit of double pump cover end
    20VQ 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14 (Viewed from shaft end of pump)

    right hand for clockwise

    left hand for counter- clockwisev
    10
    25VQ 10, 12, 14, 15, 17, 19, 21, 25
    35VQ 21, 25, 30, 32, 35, 38, 45
    45VQ 42, 45, 50, 57, 60, 66, 75

    Note 1: USgpm Flow(USgpm) at 1200r/min and 0.69MPa.

    Note 2: The data of relevant series, model are unanimous. Please see VQ series-single pumps data.

    Vq-Series
    NO. Part Qty NO. Part Qty NO. Part Qty
    1 Sliding bearing 1 6 vane kit 10 11 outlet support plate 1
    2 Pin 2 7 Rotor 1 12 Retainer 1
    3 Hexagon socket head cap screws 2 8 cam ring 1 13 O shape retainer 1
    4 inlet support plate 1 9 irregular shape retainer 4 14 Retainer 1
    5 valve plate 2 10 O shape retainer 4

    Specifications

    Series φA B C φD E φF φG H K M(Gasket) N(O-Ring)
    20VQ 82.55 81.5 70.1 47.2 61.5 4.8 76.2 7 73.8 82.76×76.26×3.5 40×3.55
    25VQ 96.8 98.8 87 52.2 71.2 4.8 90.5 7 88.19 97×91×3.5 44×3.53
    35VQ 114.3 117.7 105 72.2 90.3 6.4 108 7 103.94 114.5×108.5×3.5 63.09×3.53
    45VQ 133.35 141.1 129.6 80.2 105.5 6.4 127 11 123.8 133.6×127.6×3.5 71×3.55
    Series Inside spline tooth outline parameter of rotor
    Number of teeth Pitch Pressure angle Major diameter Minor diameter
    20VQ 30 48/96 45° 16.617 15.56
    25VQ 40 48/96 45° 21.9 20.86
    35VQ 37 40/80 45° 24.38 23.10
    45VQ 14 12/24 30° 32.59 27.6

    Frequently Asked Questions (FAQ)

    Q What is the VQ Series Cartridge Kit used for?

    The VQ Series Cartridge Kit is designed as a replacement part for Eaton Vickers hydraulic vane pumps. It allows for quick and easy servicing of the pump's inner rotating elements (including the rotor, vanes, and cam ring) without needing to replace the entire pump housing.

    Q How do I identify the correct rotation for my VQ cartridge?

    The rotation is determined by viewing the pump from the shaft end. In the model designation code, "R" stands for Right-Hand (clockwise) rotation, and "L" (or left-hand) represents Counter-Clockwise rotation.

    Q What fluid types are compatible with these cartridge kits?

    Standard cartridges (no prefix marking) are compatible with petroleum-based series oils, water-glycol fluids, and emulsification fluids. For systems utilizing synthetic phosphate ester fluids, you must specify the "F3-" prefix version.

    Q What is the difference between PC and PCT cartridge designations?

    "PC" designates a cartridge kit built for single pumps or the shaft end of double pumps. "PCT" designates a cartridge kit designed specifically for the cover end of double pumps.

    Q How is the displacement value measured in the VQ series?

    The displacement value in the model designation represents the nominal flow rate in USgpm measured at 1200 r/min and a pressure of 0.69 MPa.