Leave Your Message

High Performance Vickers V Vq Single Stage Hydraulic Vane Pumps - China Suppliers & Factory for Machinery Applications

Discover our high-performance intra-vane pumps, specifically designed for plastic injection machinery, shoe manufacturing equipment, tool machinery, die casting machinery, and various metallurgical applications. As a leading factory in China, we pride ourselves on being top suppliers of reliable and efficient pumping solutions, ensuring optimal performance and durability for your machinery needs. Choose our pumps for unmatched quality and service

    Vickers V Vq Single Stage Hydraulic Vane Pump 20V 25V 35V 45V (4)
    Vickers V Vq Single Stage Hydraulic Vane Pump 20V 25V 35V 45V (5)
    Vickers V Vq Single Stage Hydraulic Vane Pump 20V 25V 35V 45V(2)
    Vickers V Vq Single Stage Hydraulic Vane Pump 20V 25V 35V 45V(3)
    Vickers-V-Vq-Single-Stage-Hydraulic
    NO. Part Qty NO. Part Qty NO. Part Qty
    1 straight key 1 5 gasket 1 9 cartridge 1
    2 shaft 1 6 Ball bearing 1 10 O ring 1
    3 Front cover 1 7 pile type retainer 1 11 Rear cover 1
    4 shaft seal 1 8 cir clip for shaft 1 12 hexagon headed bolt 4

    Model Designation

    Vickers-V-Vq-Single-Stage-Hydraulic
    (F3-) 25V 19 A -1 A 22 R
    Note Series Flow code Port connections Shaft type Outlet positions Design number Rotation
    No-marking: Petroleum series oil emulsification fluid

    water glycol-fluid

    F3:

    phosphate ester fluid
    20V 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14 A-SAE 4-bolt flange 1-Str key 151-Spline (Viewed from cover end of pump)

    A-Opposite inlet

    B-90° CCW from inlet

    C-Inline with inlet

    D-90° CW from inlet
    22 (Viewed from shaft end of pump)

    R-right hand for clockwise

    L-left hand for counter-clockwise
    25V 10, 12, 14, 15, 17, 19, 21, 25 1-Str key

    86-HD Str key 11-Spline
    35V 21, 25, 30, 32, 35, 38, 45
    45V 42, 45, 50, 57, 60, 66, 75
    USgpm Flow(USgpm) at 1200r/min and 0.69MPa

    Technical Data

    Series Flow code (USgpm) Geometric displacement mL/r(in³/r) With antiwear hydraulic oil / phosphate ester fluid With water glycol fluid With water-oil emulsions Min. speed
    Max.operating pressure MPa Max.speed r/min Max.operating pressure MPa Max.speed r/min Max.operating pressure MPa Max.speed r/min
    20V 2 7.5(0.46) 13.8 1800 13.8 1500 6.9 1200 600
    3 10(0.61)
    4 13(0.79) 20.7 15.9
    5 16.5(1.01)
    6 19(1.16)
    7 23(1.40)
    8 27(1.67)
    9 30(1.85)
    10 32(1.95)
    11 36(2.20)
    12 40(2.44) 15.9 13.8
    14 45(2.78) 13.8
    25V 10 32.5(1.98) 17.2 1800 15.9 1500 6.9 1500 600
    12 39(2.38)
    14 45(2.78)
    15 47(2.89)
    17 55(3.36)
    19 60(3.66)
    21 67(4.13)
    25 81(4.94)
    35V 21 67(4.13) 17.2 1800 15.9 1500 6.9 1500 600
    25 81(4.94)
    30 97(5.91)
    32 101(6.16)
    35 112(6.83)
    38 121(7.37)
    45 147(8.95) 13.8 13.8
    45V 42 138(8.41) 17.2 1800 15.9 1500 6.9 1500 600
    45 147(8.95)
    50 162(9.85)
    57 181(11.05)
    60 193(11.75)
    66 212(12.93)
    75 237(14.46) 13.8 13.8

    Installation Dimensions

    Vickers-V-Vq-Single
    Vickers-V-Vq-Single-Stage
    Vickers-V-Vq-Single

    Frequently Asked Questions (FAQ)

    What are the main series included in the Vickers V/VQ single stage hydraulic vane pumps?

    The Vickers V/VQ single stage hydraulic vane pump series includes the 20V, 25V, 35V, and 45V models, designed for different flow rates and displacement requirements.

    What types of fluids are compatible with Vickers V/VQ vane pumps?

    These pumps are compatible with petroleum series oil, emulsification fluids, water glycol fluids, and phosphate ester fluids (designated by the "F3-" prefix).

    What is the maximum operating pressure for the Vickers 20V series pump?

    For the 20V series, the maximum operating pressure reaches up to 20.7 MPa when using antiwear hydraulic oil, depending on the specific flow code selected.

    How do I determine the shaft rotation of a Vickers V/VQ pump?

    Rotation is viewed from the shaft end of the pump. It is designated by "R" for right-hand (clockwise) rotation and "L" for left-hand (counter-clockwise) rotation.

    What shaft options are available for the 25V, 35V, and 45V series?

    Available shaft options include the 1-Str (straight) key, 86-HD Str (heavy duty straight) key, and 11-Spline configurations.

    What is the minimum operating speed for the Vickers V/VQ series pumps?

    The minimum operating speed for the 20V, 25V, 35V, and 45V series pumps is 600 r/min across standard fluid applications.