0102030405
High-Performance Tokimeco Treble Vane Pump SQP Series - Low Noise China Suppliers & Factory Solutions
Model Designation
| (F3-) | SQP321 | -35 | -17 | 5 | -86 | CCC | (F) | -(LH) | -18 |
| Infuse front, oil intermiscibility | Series | Flow-shaft end code | Flow-mid code | Flow-cover end pump port connetion | Shaft type | Port positions | Installation type | Rotation | Design number |
| No-marking: Anti-wear hydraulic oil, Water glycol fluid or water-oil emulsions F3-phosphate ester fluid |
SQP321 |
21, 25, 30, 32, 35, 38, 45 | 10, 12, 14, 15, 17, 19, 21, 25 | 2, 3, 4, 5, 6, 7, 8 |
86-Heavy belt key straight shaft | See below | No-marking: Flange Mounting F-Foot Mountion |
(Viewed from shaft end of pump) LH-Left hand for counter clockwise No marking-Rihgt hand for clockwise |
18 |
SQP421 |
42, 45, 50, 57, 60, 66, 75 | 10, 12, 14, 15, 17, 19, 21, 25 | 2, 3, 4, 5, 6, 7, 8 |
||||||
SQP431 |
42, 45, 50, 57, 60, 66, 75 | 21, 25, 30, 32, 35, 38, 45 | 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 14 | ||||||
SQP432 |
42, 45, 50, 57, 60, 66, 75 | 21, 25, 30, 32, 35, 38, 45 | 10, 12, 14, 15, 17, 19, 21, 25 |
USgpm Flow(USgpm) at 1200r/min and 0.69MPa.
Outlet Positions (Viewed from cover end of pump)
| No.1 outlet positions | |
| A | opposite inlet |
| B | 90° CCW from inlet |
| C | Inline with inlet |
| D | 90° CW from inlet |
|
SQP321、SQP421 No.2 Outlet positions |
SQP431、SQP432 No.2 Outlet positions |
|
| A | N0.2 outlet 135° CCW from inlet | N0.2 outlet opposite inlet |
| B | N0.2 outlet 45° CCW from inlet | N0.2 outlet 90° CCW from inlet |
| C | N0.2 outlet 45° CW from inlet | N0.2 outlet inline with inlet |
| D | N0.2 outlet 135° CW from inlet | N0.2 outlet 90° CW from inlet |
|
SQP321、SQP421 No.3 Outlet positions |
SQP431、SQP432 No.3 Outlet positions |
|
| A | N0.3 outlet opposite inlet | 135° N0.3 outlet 135°CCW from inlet |
| B | N0.3 outlet 90°CCW from inlet | NO.3 outlet 45° CCW from inlet |
| C | N0.3 outlet inline with inlet | N0.3 outlet 45° CW from inlet |
| D | N0.3 outlet 90° CW from inlet | N0.3 outlet 135°CW from inlet |
Frequently Asked Questions
Q
What does the "F3-" prefix represent in the model designation?
The "F3-" prefix indicates that the pump is designated for phosphate ester fluid. If there is no marking prefix, the pump is suitable for anti-wear hydraulic oil, water glycol fluid, or water-oil emulsions.
Q
What type of shaft does the designation code "86" indicate?
The designation code "86" refers to a heavy belt key straight shaft type.
Q
How are rotation directions designated for the SQP series pumps?
Viewed from the shaft end of the pump, "LH" stands for left hand (counter-clockwise) rotation, whereas no marking stands for right hand (clockwise) rotation.
Q
What are the standard configurations for the No.1 outlet positions?
The No.1 outlet positions are designated as: A (opposite inlet), B (90° CCW from inlet), C (inline with inlet), and D (90° CW from inlet).
Q
How do No.2 outlet positions differ between SQP321/421 and SQP431/432?
For SQP321 and SQP421, Position A is 135° CCW from inlet, Position B is 45° CCW from inlet, Position C is 45° CW from inlet, and Position D is 135° CW from inlet. For SQP431 and SQP432, Position A is opposite inlet, Position B is 90° CCW from inlet, Position C is inline with inlet, and Position D is 90° CW from inlet.
Q
Under what conditions is the flow rate (USgpm) measured?
The USgpm flow rate is measured at a speed of 1200 r/min and a pressure of 0.69 MPa.