In mobile cranes, how well the hydraulics work affects how much weight the crane can lift, how accurately it can control the movement, and how safe it is to operate. The V2020 double pump is specially designed to handle these tough challenges. It usually powers two separate parts of the system:

    Application in Mobile Cranes

    The main lifting and handling system: The bigger part of the pump is used for the crane’s main tasks, like controlling the main hoist, extending and pulling in the boom. This part needs a steady and controlled flow of hydraulic fluid to move loads smoothly and precisely, and it also needs to handle high pressure to lift heavy weights. The pump keeps giving a steady flow, so the crane moves without stopping or jerking, even when it's lifting the heaviest loads. This is very important for keeping the crane safe and stable.
    The second, typically smaller, pump section manages essential auxiliary systems at the same time and on its own. It powers the outriggers to create a stable base, controls the superstructure for smooth 360-degree rotation, and sometimes handles the steering of the carrier vehicle. This separate system is crucial. It enables the operator to safely perform tasks by extending the outriggers while simultaneously reducing setup time and improving overall job site efficiency. The reliability of the V2020 ensures these important functions are always accessible.
    • cranes
    • heavy-machinery
    • machine-tool
    • mobile-cranes
    • Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (1)
    • Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (2)
    • Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (4)
    • Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (5)

    Model Designation

    (F3-)

    V2010

    -1

    F

    13

    S

    3

    S

    -1

    CC

    -12

    -R

    Note

    Series

    Mounting

    Inlet port connections

    Flow-Shaft end pump

    No. 1

    outlet port

    Flow-cover end pump

    No. 2

    outlet port

    Shaft type

    Outlet positions

    Design number

    Rotation

    Omit if not

    Required

     F3-:

    Viton seals

     

    V2010

    1- SAE B

    2 bolt flange

    4" rabbet

    6- SAE C

    2 bolt flange

    3.25" rabbet

     

     

     

    F- 4

     bolt flange

     

     

     

    6, 7, 8, 9,

    10, 11, 12, 13

     

     

     

    S-1.062- 12UN-

    2Bthd

     

    1, 2, 3, 4, 5,

    6, 7

     

    S-.750-16

    St.Thd.

     

     

    -1 Str key

     

    -11 spline

     

     

     

    see below

     

     

     

     

    -12

    (Viewed from shaft end of pump)

    -R right     hand for clockwise

    -L left hand for counter- clockwise

     

    V2020

     

    6, 7, 8, 9, 10,

    11, 12, 13

     

    S-1.062-

    12 St.Thd.


    Technical Data

    Outlet positions

    V2010

    V2020

     

    No.1 outlet opposite inlet

    AA

    1350 No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    AB

    No.2 outlet 450 CCW from inlet

     No.2 outlet 900 CCW from inlet

    AC

     No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    AD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

     

     

     No.1 outlet 900  CCW from inlet

    BA

     No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    BB

    No.2 outlet 450 CCW from inlet

     No.2 outlet 900 CCW from inlet

    BC

     No.2 outlet 450 CW from inlet

     No.2 outlet inline with inlet

    BD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

     

    No.1 outlet inline with inlet

    CA

    No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    CB

     No.2 outlet 450 CCW from inlet

     No.2 outlet 900 CCW from inlet

    CC

     No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    CD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

     

     

     No.1 outlet 900  CW from inlet

    DA

     No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    DB

     No.2 outlet 450 CCW from inlet

    No.2 outlet 900 CCW from inlet

    DC

     No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    DD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

    Eaton-Vickers-Vane-Double-Pump-V2010
    USgpm Dimension
     Shaft end Cover end

    A

    B

    C

     

    7, 8, 9

    1, 2, 3, 4, 5, 6, 7 213.0 219.1 224.1 190.0 196.1 201.1  

    113.5

     

    10, 11

    1, 2, 3, 4, 5, 6, 7 218.2 224.1 229.1 195.0 201.1 206.1  

    118.5

     

    12, 13

    1, 2, 3, 4, 5, 6, 7 222.0 228.1 233.1 199.0 205.1 210.1  

    121.5

    Eaton-Vickers-Vane-Double-Pump-V2010-V2020
    USgpm Dimension
    Shaft end  Cover end

    A

    B

    C

    7, 8, 9

    6, 7, 8, 9 213.4 219.5 187.7 193.8

    114.0

     

    10, 11

    6, 7, 8, 9, 10, 11 218.4 224.5 229.5 192.7 198.8 203.8  

    119.0

     

    12, 13

    6, 7, 8, 9, 10, 11 222.4 228.5 233.5 196.7 202.8 207.8  

    122.5

    Splined Shaft Type

    V2010, 2020 Series Double Pumps (3)
    V2010, 2020 Series Double Pumps (4)
    Eaton-Vickers-Vane1
    Involute spline data table
     Model

    Shaft code

    Number of teeth  Pitch

    Major diameter

    Pitch diameter

    Minor diameter

     Suitable for

    11

    9

    16/32

    15.82/15.80 14.29

    12.28/12.00

    Tooth tip

    V10

    38

    11

    16/32

    18.63/18.50 17.46

    15.24/14.99

    Tooth side

    11

    11

    16/32

    19.01/18.93 17.46

    15.90/15.62

    Tooth side

    V20

    38

    11

    16/32

    18.63/18.50 17.46

    15.24/14.99

    Tooth side

    62

    9

    16/32

    15.82/15.80 14.29

    12.28/12.00

    Tooth tip

    V2010 V2020

    11

    13

    16/32

    22.17/22.15 19.03

    18.63/18.35

    Tooth tip