In the world of mobile cranes, the performance of hydraulic systems is crucial for determining the lifting capacity, control precision, and overall safety during operation. The V2020 double pump is engineered to meet these demanding challenges effectively. Manufactured by leading suppliers in China, this robust pump typically powers two distinct components of the crane's hydraulic system, ensuring optimal functionality and reliability. As a trusted factory in the field, we prioritize quality and innovation to support your lifting needs with confidence

    Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (1)
    Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (2)
    Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (4)
    Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (5)

    Model Designation

    (F3-)

    V2010

    -1

    F

    13

    S

    3

    S

    -1

    CC

    -12

    -R

    Note

    Series

    Mounting

    Inlet port connections

    Flow-Shaft end pump

    No. 1 outlet port

    Flow-cover end pump

    No. 2 outlet port

    Shaft type

    Outlet positions

    Design number

    Rotation

    Omit if not required

    F3-: Viton seals

    V2010

    1- SAE B 2 bolt flange 4" rabbet

    6- SAE C 2 bolt flange 3.25" rabbet

    F- 4 bolt flange

    6, 7, 8, 9, 10, 11, 12, 13

    S-1.062- 12UN-2Bthd

    1, 2, 3, 4, 5, 6, 7

    S-.750-16 St.Thd.

    -1 Str key

    -11 spline

    see below

    -12

    (Viewed from shaft end of pump)

    -R right hand for clockwise

    -L left hand for counter-clockwise

    V2020

    6, 7, 8, 9, 10, 11, 12, 13

    S-1.062-12 St.Thd.

    Technical Data

    Outlet positions

    V2010

    V2020

    No.1 outlet opposite inlet

    AA

    1350 No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    AB

    No.2 outlet 450 CCW from inlet

    No.2 outlet 900 CCW from inlet

    AC

    No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    AD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

    No.1 outlet 900 CCW from inlet

    BA

    No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    BB

    No.2 outlet 450 CCW from inlet

    No.2 outlet 900 CCW from inlet

    BC

    No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    BD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

    No.1 outlet inline with inlet

    CA

    No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    CB

    No.2 outlet 450 CCW from inlet

    No.2 outlet 900 CCW from inlet

    CC

    No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    CD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

    No.1 outlet 900 CW from inlet

    DA

    No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    DB

    No.2 outlet 450 CCW from inlet

    No.2 outlet 900 CCW from inlet

    DC

    No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    DD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

    Eaton-Vickers-Vane-Double-Pump-V2010
    USgpm Dimension
    Shaft end Cover end

    A

    B

    C

    7, 8, 9

    1, 2, 3, 4, 5, 6, 7 213.0
    219.1
    224.1
    190.0
    196.1
    201.1

    113.5

    10, 11

    1, 2, 3, 4, 5, 6, 7 218.2
    224.1
    229.1
    195.0
    201.1
    206.1

    118.5

    12, 13

    1, 2, 3, 4, 5, 6, 7 222.0
    228.1
    233.1
    199.0
    205.1
    210.1

    121.5

    Eaton-Vickers-Vane-Double-Pump-V2010-V2020
    USgpm Dimension
    Shaft end Cover end

    A

    B

    C

    7, 8, 9

    6, 7, 8, 9 213.4
    219.5
    187.7
    193.8
    114.0

    10, 11

    6, 7, 8, 9, 10, 11 218.4
    224.5
    229.5
    192.7
    198.8
    203.8
    119.0

    12, 13

    6, 7, 8, 9, 10, 11 222.4
    228.5
    233.5
    196.7
    202.8
    207.8
    122.5

    Splined Shaft Type

    V2010, 2020 Series Double Pumps (3)
    V2010, 2020 Series Double Pumps (4)
    Eaton-Vickers-Vane1
    Involute spline data table
    Model

    Shaft code

    Number of teeth Pitch

    Major diameter

    Pitch diameter

    Minor diameter

    Suitable for

    11

    9

    16/32

    15.82/15.80 14.29

    12.28/12.00

    Tooth tip

    V10

    38

    11

    16/32

    18.63/18.50 17.46

    15.24/14.99

    Tooth side

    11

    11

    16/32

    19.01/18.93 17.46

    15.90/15.62

    Tooth side

    V20

    38

    11

    16/32

    18.63/18.50 17.46

    15.24/14.99

    Tooth side

    62

    9

    16/32

    15.82/15.80 14.29

    12.28/12.00

    Tooth tip

    V2010 V2020

    11

    13

    16/32

    22.17/22.15 19.03

    18.63/18.35

    Tooth tip

    Frequently Asked Questions (FAQ)

    Q What does the "F3-" prefix represent in the V2010/V2020 model designation?
    The "F3-" prefix indicates that the pump is equipped with Viton seals, which are ideal for high-temperature applications or specific hydraulic fluids. If Viton seals are not required, this prefix can be omitted.
    Q How can I identify the rotation configuration of these vane double pumps?
    Pump rotation is determined by viewing the unit from the shaft end. A model code ending with "-R" indicates right-hand (clockwise) rotation, while "-L" indicates left-hand (counter-clockwise) rotation.
    Q What are the standard shaft configurations available for V2010 and V2020 series?
    These double pumps are commonly available with two main shaft types: a straight keyed shaft (Shaft Code -1) and a splined shaft (Shaft Code -11).
    Q How do the flow capacities differ between the shaft end and cover end of V2010 and V2020 pumps?
    For the shaft end pump, flow capacities range from 6 to 13 USgpm. For the cover end pump, the V2010 series supports 1 to 7 USgpm, whereas the V2020 series supports 6 to 11 USgpm.
    Q What mounting options are available for the V2010 and V2020 series?
    Standard mounting options include mounting code "1" for an SAE B 2-bolt flange with a 4" rabbet, and mounting code "6" for an SAE C 2-bolt flange with a 3.25" rabbet.
    Q Can the outlet ports be oriented in different positions?
    Yes, the outlet positions are highly customizable. Depending on the model designation code (e.g., AA, AB, CC), the No. 1 and No. 2 outlet ports can be positioned opposite, inline, or at 90-degree/135-degree angles relative to the inlet.

    Leave Your Message