Eaton Vickers V2020 Double Pump - Hydraulic Oil Pump from China Suppliers and Factory for Mobile Cranes

In mobile cranes, the efficiency of the hydraulics plays a crucial role in determining the lifting capacity, movement precision, and operational safety. The V2020 double pump is expertly engineered to meet these demanding requirements, making it an essential component for crane performance. Manufactured in China, this high-quality pump typically powers two critical parts of the hydraulic system, ensuring reliable operation. As a leading supplier in the industry, we take pride in our state-of-the-art factory, producing hydraulic solutions that enhance the functionality and safety of mobile cranes worldwide

    Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (1)
    Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (2)
    Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (4)
    Eaton Vickers Vane Double Pump V2010 V2020 Hydraulic Oil Pump Bomba (5)

    Model Designation

    (F3-)

    V2010

    -1

    F

    13

    S

    3

    S

    -1

    CC

    -12

    -R

    Note

    Series

    Mounting

    Inlet port connections

    Flow-Shaft end pump

    No. 1 outlet port

    Flow-cover end pump

    No. 2 outlet port

    Shaft type

    Outlet positions

    Design number

    Rotation

    Omit if not Required

    F3-: Viton seals

    V2010

    1- SAE B 2 bolt flange 4" rabbet

    6- SAE C 2 bolt flange 3.25" rabbet

    F- 4 bolt flange

    6, 7, 8, 9, 10, 11, 12, 13

    S-1.062- 12UN-2Bthd

    1, 2, 3, 4, 5, 6, 7

    S-.750-16 St.Thd.

    -1 Str key

    -11 spline

    see below

    -12

    (Viewed from shaft end of pump)

    -R right hand for clockwise

    -L left hand for counter-clockwise

    V2020

    6, 7, 8, 9, 10, 11, 12, 13

    S-1.062-12 St.Thd.

    Technical Data

    Outlet positions

    V2010

    V2020

    No.1 outlet opposite inlet

    AA

    1350 No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    AB

    No.2 outlet 450 CCW from inlet

    No.2 outlet 900 CCW from inlet

    AC

    No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    AD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

    No.1 outlet 900 CCW from inlet

    BA

    No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    BB

    No.2 outlet 450 CCW from inlet

    No.2 outlet 900 CCW from inlet

    BC

    No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    BD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

    No.1 outlet inline with inlet

    CA

    No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    CB

    No.2 outlet 450 CCW from inlet

    No.2 outlet 900 CCW from inlet

    CC

    No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    CD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

    No.1 outlet 900 CW from inlet

    DA

    No.2 outlet 1350 CCW from inlet

    No.2 outlet opposite inlet

    DB

    No.2 outlet 450 CCW from inlet

    No.2 outlet 900 CCW from inlet

    DC

    No.2 outlet 450 CW from inlet

    No.2 outlet inline with inlet

    DD

    No.2 outlet 1350 CW from inlet

    No.2 outlet 900 CW from inlet

    Eaton-Vickers-Vane-Double-Pump-V2010
    USgpm Dimension
    Shaft end Cover end A B C

    7, 8, 9

    1, 2, 3, 4, 5, 6, 7 213.0
    219.1
    224.1
    190.0
    196.1
    201.1

    113.5

    10, 11

    1, 2, 3, 4, 5, 6, 7 218.2
    224.1
    229.1
    195.0
    201.1
    206.1

    118.5

    12, 13

    1, 2, 3, 4, 5, 6, 7 222.0
    228.1
    233.1
    199.0
    205.1
    210.1

    121.5

    Eaton-Vickers-Vane-Double-Pump-V2010-V2020
    USgpm Dimension
    Shaft end Cover end A B C

    7, 8, 9

    6, 7, 8, 9 213.4
    219.5
    187.7
    193.8

    114.0

    10, 11

    6, 7, 8, 9, 10, 11 218.4
    224.5
    229.5
    192.7
    198.8
    203.8

    119.0

    12, 13

    6, 7, 8, 9, 10, 11 222.4
    228.5
    233.5
    196.7
    202.8
    207.8

    122.5

    Splined Shaft Type

    V2010, 2020 Series Double Pumps (3)
    V2010, 2020 Series Double Pumps (4)
    Eaton-Vickers-Vane1
    Involute spline data table
    Model

    Shaft code

    Number of teeth Pitch

    Major diameter

    Pitch diameter

    Minor diameter

    Suitable for

    11

    9

    16/32

    15.82/15.80 14.29

    12.28/12.00

    Tooth tip

    V10

    38

    11

    16/32

    18.63/18.50 17.46

    15.24/14.99

    Tooth side

    11

    11

    16/32

    19.01/18.93 17.46

    15.90/15.62

    Tooth side

    V20

    38

    11

    16/32

    18.63/18.50 17.46

    15.24/14.99

    Tooth side

    62

    9

    16/32

    15.82/15.80 14.29

    12.28/12.00

    Tooth tip

    V2010 V2020

    11

    13

    16/32

    22.17/22.15 19.03

    18.63/18.35

    Tooth tip

    Frequently Asked Questions (FAQ)
    Q1: What is the main configuration difference between Eaton Vickers V2010 and V2020 double pumps?
    A1: The V2010 configuration combines a V20 series pump on the shaft end with a smaller V10 series pump on the cover end. The V2020 configuration features V20 series pumps on both the shaft end and the cover end, allowing for higher flow capacity on the secondary outlet.
    Q2: How do I identify if the pump has Viton seals from the model code?
    A2: If the model designation starts with the prefix "F3" (e.g., F3-V2010), it indicates that the pump is equipped with Viton seals, which are ideal for special synthetic fluids and high-temperature environments. If the prefix is omitted, standard seals are used.
    Q3: What mounting flange options are available for the V2010 and V2020 series?
    A3: The mounting code "1" indicates an SAE B 2-bolt flange with a 4" rabbet diameter, while code "6" indicates an SAE C 2-bolt flange with a 3.25" rabbet diameter.
    Q4: How is the rotation direction determined for these double vane pumps?
    A4: Rotation is determined when looking directly at the shaft end of the pump. The suffix "-R" indicates right-hand (clockwise) rotation, whereas the suffix "-L" indicates left-hand (counter-clockwise) rotation.
    Q5: Can the outlet port positions be adjusted or configured differently?
    A5: Yes, the outlet positions are highly configurable. By using different position codes (such as AA, AB, CC, etc.), you can position the No.1 and No.2 outlets at various angles (inline, opposite, 90° CW/CCW, or 135° CW/CCW) relative to the main inlet.
    Q6: What spline shaft options are compatible with V2010 and V2020 double pumps?
    A6: These pumps support a 13-tooth spline shaft (shaft code 11) with a 16/32 pitch, a major diameter of 22.17/22.15 mm, and a pitch diameter of 19.03 mm, designed for tooth tip fitment.