Model Designation
| (F3-) | SQP32 | -35 | -17 | -86 | CD | (F) | -(LH) | -18 |
| Infuse front, oil intermiscibility | Series | Displacement code of shaft end pump | Displacement code of cover end pump | Shaft type | Port positions | Installation type | Rotation | Design number |
| No-marking: Anti-wear hydraulic oil, Water glycol fluid or water-oil emulsions F3- phosphate ester fluid |
SQP21 | 10, 12, 14, 15, 17, 19, 21, 25 | 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14 | 1-Belt key straight shaft 86-Heavy belt key straight shaft |
See below | No-marking: Flange Mounting F-Foot Mountion |
(Viewed from shaft end of pump) LH-Left hand for counter clockwise No marking-Right hand for clockwise |
18 |
| SQP31 | 21, 25, 30, 32, 35, 38, 45 | 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14 | ||||||
| SQP32 | 21, 25, 30, 32, 35, 38, 45 | 10, 12, 14, 15, 17, 19, 21, 25 | ||||||
| SQP41 | 42, 45, 50, 57, 60, 66, 75 | 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14 | ||||||
| SQP42 | 42, 45, 50, 57, 60, 66, 75 | 10, 12, 14, 15, 17, 19, 21, 25 | ||||||
| SQP43 | 42, 45, 50, 57, 60, 66, 75 | 21, 25, 30, 32, 35, 38, 45 |
USgpm Flow(USgpm) at 1200r/min and 0.69MPa.
Noise Data
Outlet Positions (Viewed from cover end of pump)
| Port positions | All series (except SQP43) | SQP43 series | |
| No.1 outlet opposite inlet | AA | No.2 outlet 135°CCW from inlet | No.2 outlet opposite inlet |
| AB | No.2 outlet 45°CCW from inlet | No.2 outlet 90°CCW from inlet | |
| AC | No.2 outlet 45°CW from inlet | No.2 outlet inline with inlet | |
| AD | No.2 outlet 135°CW from inlet | No.2 outlet 90°CW from inlet | |
| No.1 outlet 90° CCW from inlet | BA | No.2 outlet 135°CCW from inlet | No.2 outlet opposite inlet |
| BB | No.2 outlet 45°CCW from inlet | No.2 outlet 90°CCW from inlet | |
| BC | No.2 outlet 45°CW from inlet | No.2 outlet inline with inlet | |
| BD | No.2 outlet 135°CW from inlet | No.2 outlet 90°CW from inlet | |
| No.1 outlet inline with inlet | CA | No.2 outlet 135°CCW from inlet | No.2 outlet opposite inlet |
| CB | No.2 outlet 45°CCW from inlet | No.2 outlet 90°CCW from inlet | |
| CC | No.2 outlet 45°CW from inlet | No.2 outlet inline with inlet | |
| CD | No.2 outlet 135°CW from inlet | No.2 outlet 90°CW from inlet | |
| No.1 outlet 90°CW from inlet | DA | No.2 outlet 135°CCW from inlet | No.2 outlet opposite inlet |
| DB | No.2 outlet 45°CCW from inlet | No.2 outlet 90°CCW from inlet | |
| DC | No.2 outlet 45°CW from inlet | No.2 outlet inline with inlet | |
| DD | No.2 outlet 135°CW from inlet | No.2 outlet 90°CW from inlet | |
Technical Data
| Series | Shaft end pump (No.1 outlet) | Cover end pump (No.2 outlet) | Max. speed r/min | Min. speed r/min | ||||
| Displacement code | Geometric displacement mL/r | Max. pressure MPa | Displacement code | Geometric displacement mL/r | Max. pressure MPa | |||
| SQP21 | 10 | 32.5 | As SQP2 | 2 | 7.5 | As SQP1 | As SQP Series single pumps | 600 |
| 12 | 38.3 | |||||||
| 14 | 43.3 | 3 | 10.2 | |||||
| 15 | 46.7 | |||||||
| 17 | 52.5 | 4 | 12.8 | |||||
| 19 | 59.2 | |||||||
| 21 | 65.0 | 5 | 16.7 | |||||
| 25 | 79.2 | |||||||
| SQP31 | 21 | 66.7 | As SQP3 | 6 | 19.2 | |||
| 25 | 79.2 | 7 | 22.9 | |||||
| 30 | 95.0 | |||||||
| 32 | 100 | 8 | 26.2 | |||||
| 35 | 109 | |||||||
| 38 | 118 | 9 | 28.8 | |||||
| 45 | 140 | |||||||
| SQP41 | 42 | 134 | As SQP4 | 10 | 31.0 | |||
| 45 | 140 | |||||||
| 50 | 156 | 11 | 35.0 | |||||
| 57 | 178 | |||||||
| 60 | 189 | 12 | 37.9 | |||||
| 66 | 207 | 14 | 44.2 | |||||
| 75 | 237 | |||||||
| SQP32 | 21 | 66.7 | As SQP3 | 10 | 32.5 | As SQP2 | As SQP Series single pumps | 600 |
| 25 | 79.2 | |||||||
| 30 | 95.0 | 12 | 38.3 | |||||
| 32 | 100 | |||||||
| 35 | 109 | 14 | 43.3 | |||||
| 38 | 118 | |||||||
| 45 | 140 | 15 | 46.7 | |||||
| SQP42 | 42 | 134 | As SQP4 | 17 | 52.5 | |||
| 45 | 140 | |||||||
| 50 | 156 | 19 | 59.2 | |||||
| 57 | 178 | |||||||
| 60 | 189 | 21 | 65.0 | |||||
| 66 | 207 | |||||||
| 75 | 237 | 25 | 79.2 | |||||
| SQP43 | 42 | 134 | As SQP4 | 21 | 66.7 | As SQP3 | As SQP Series single pumps | 600 |
| 45 | 140 | 25 | 79.2 | |||||
| 50 | 156 | 30 | 95.0 | |||||
| 57 | 178 | 32 | 100 | |||||
| 60 | 189 | 35 | 109 | |||||
| 66 | 207 | 38 | 118 | |||||
| 75 | 237 | 45 | 140 | |||||
| USgpm Flow(USgpm) at 1200r/min and 0.69MPa | ||||||||
| Permit surpassing the top pressure 10% instantaneous pressure, within 0.5 second. | ||||||||
Frequently Asked Questions
What is the difference between standard and F3- prefix models?
Standard models (no marking) are designed for use with anti-wear hydraulic oil, water glycol fluid, or water-oil emulsions. The F3- prefix designates compatibility with phosphate ester fluids.
How are the displacement codes mapped to actual flow rates?
Displacement codes indicate the nominal flow rate in USgpm at 1200 r/min and 0.69 MPa. For exact geometric displacement in mL/r, please refer to the Technical Data table.
What mounting options are available for the SQP series?
By default, the pumps are configured for Flange Mounting. If you require Foot Mounting, specify the "F" designator in the model code.
Can the outlet port positions be adjusted?
Yes, multiple port positions can be selected (e.g., inline, opposite, 90° or 135° clockwise/counter-clockwise relative to the inlet) depending on the specific SQP series. Consult the Outlet Positions chart for details.
What is the speed range for these double-stage vane pumps?
The minimum operating speed for all SQP series pumps is 600 r/min, while the maximum speed depends on the single pump configurations within the series.