Leave Your Message

China Suppliers Factory Tokimec SQP Series Double Stage Hydraulic Vane Pump for Precision Machining Applications

In the competitive landscape of precision machining, where every micron counts and energy costs are on the rise, the hydraulic system plays a crucial role. It is essential for it to provide reliability, efficiency, and quiet operation. The TOKIMEC SQP series double pump configuration is expertly designed to fulfill these stringent requirements, making it the perfect hydraulic solution for various machine tools such as machining centers, grinders, and CNC lathes. As a leading choice among China manufacturers and suppliers, our factory ensures that you receive a product that combines state-of-the-art technology with exceptional performance to elevate your machining processes

    Albert Double Stage Hydraulic Vane Pump for Industrial Applications Tokimec Sqp Type Sqp43 Sqp42 Sqp41 Sqp32 Sqp31 Sqp21(4)
    Albert Double Stage Hydraulic Vane Pump for Industrial Applications Tokimec Sqp Type Sqp43 Sqp42 Sqp41 Sqp32 Sqp31 Sqp21(2)
    Albert Double Stage Hydraulic Vane Pump for Industrial Applications Tokimec Sqp Type Sqp43 Sqp42 Sqp41 Sqp32 Sqp31 Sqp21 (5)
    Albert Double Stage Hydraulic Vane Pump for Industrial Applications Tokimec Sqp Type Sqp43 Sqp42 Sqp41 Sqp32 Sqp31 Sqp21 (3)
    Albert Double Stage Hydraulic Vane Pump for Industrial Applications Tokimec Sqp Type Sqp43 Sqp42 Sqp41 Sqp32 Sqp31 Sqp21 (1)

    Model Designation

    Albert-Double-Stage
    (F3-) SQP32 -35 -17 -86 CD (F) -(LH) -18
    Infuse front, oil intermiscibility Series Displacement code of shaft end pump Displacement code of cover end pump Shaft type Port positions Installation type Rotation Design number
    No-marking: Anti-wear hydraulic oil, Water glycol fluid or water-oil emulsions

    F3- phosphate ester fluid
    SQP21 10, 12, 14, 15, 17, 19, 21, 25 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14 1-Belt key straight shaft

    86-Heavy belt key straight shaft
    See below No-marking: Flange Mounting

    F-Foot Mountion
    (Viewed from shaft end of pump)

    LH-Left hand for counter clockwise

    No marking-Right hand for clockwise
    18
    SQP31 21, 25, 30, 32, 35, 38, 45 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14
    SQP32 21, 25, 30, 32, 35, 38, 45 10, 12, 14, 15, 17, 19, 21, 25
    SQP41 42, 45, 50, 57, 60, 66, 75 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 14
    SQP42 42, 45, 50, 57, 60, 66, 75 10, 12, 14, 15, 17, 19, 21, 25
    SQP43 42, 45, 50, 57, 60, 66, 75 21, 25, 30, 32, 35, 38, 45

    USgpm Flow(USgpm) at 1200r/min and 0.69MPa.

    Noise Data

    SQP Series Double Pump detail (1)

    Outlet Positions (Viewed from cover end of pump)

    Albert-Double-Stage
    Port positions All series (except SQP43) SQP43 series
    No.1 outlet opposite inlet AA No.2 outlet 135°CCW from inlet No.2 outlet opposite inlet
    AB No.2 outlet 45°CCW from inlet No.2 outlet 90°CCW from inlet
    AC No.2 outlet 45°CW from inlet No.2 outlet inline with inlet
    AD No.2 outlet 135°CW from inlet No.2 outlet 90°CW from inlet
    No.1 outlet 90° CCW from inlet BA No.2 outlet 135°CCW from inlet No.2 outlet opposite inlet
    BB No.2 outlet 45°CCW from inlet No.2 outlet 90°CCW from inlet
    BC No.2 outlet 45°CW from inlet No.2 outlet inline with inlet
    BD No.2 outlet 135°CW from inlet No.2 outlet 90°CW from inlet
    No.1 outlet inline with inlet CA No.2 outlet 135°CCW from inlet No.2 outlet opposite inlet
    CB No.2 outlet 45°CCW from inlet No.2 outlet 90°CCW from inlet
    CC No.2 outlet 45°CW from inlet No.2 outlet inline with inlet
    CD No.2 outlet 135°CW from inlet No.2 outlet 90°CW from inlet
    No.1 outlet 90°CW from inlet DA No.2 outlet 135°CCW from inlet No.2 outlet opposite inlet
    DB No.2 outlet 45°CCW from inlet No.2 outlet 90°CCW from inlet
    DC No.2 outlet 45°CW from inlet No.2 outlet inline with inlet
    DD No.2 outlet 135°CW from inlet No.2 outlet 90°CW from inlet

    Technical Data

    Series Shaft end pump (No.1 outlet) Cover end pump (No.2 outlet) Max. speed r/min Min. speed r/min
    Displacement code Geometric displacement mL/r Max. pressure MPa Displacement code Geometric displacement mL/r Max. pressure MPa
    SQP21 10 32.5 As SQP2 2 7.5 As SQP1 As SQP Series single pumps 600
    12 38.3
    14 43.3 3 10.2
    15 46.7
    17 52.5 4 12.8
    19 59.2
    21 65.0 5 16.7
    25 79.2
    SQP31 21 66.7 As SQP3 6 19.2
    25 79.2 7 22.9
    30 95.0
    32 100 8 26.2
    35 109
    38 118 9 28.8
    45 140
    SQP41 42 134 As SQP4 10 31.0
    45 140
    50 156 11 35.0
    57 178
    60 189 12 37.9
    66 207 14 44.2
    75 237
    SQP32 21 66.7 As SQP3 10 32.5 As SQP2 As SQP Series single pumps 600
    25 79.2
    30 95.0 12 38.3
    32 100
    35 109 14 43.3
    38 118
    45 140 15 46.7
    SQP42 42 134 As SQP4 17 52.5
    45 140
    50 156 19 59.2
    57 178
    60 189 21 65.0
    66 207
    75 237 25 79.2
    SQP43 42 134 As SQP4 21 66.7 As SQP3 As SQP Series single pumps 600
    45 140 25 79.2
    50 156 30 95.0
    57 178 32 100
    60 189 35 109
    66 207 38 118
    75 237 45 140
    USgpm Flow(USgpm) at 1200r/min and 0.69MPa
    Permit surpassing the top pressure 10% instantaneous pressure, within 0.5 second.
    Albert-Double-Stage
    Albert-Double-Stage
    Albert-Double-Stage
    Albert-Double-Stage
    Albert-Double-Stage
    Albert-Double-Stage

    Frequently Asked Questions

    What is the difference between standard and F3- prefix models?
    Standard models (no marking) are designed for use with anti-wear hydraulic oil, water glycol fluid, or water-oil emulsions. The F3- prefix designates compatibility with phosphate ester fluids.
    How are the displacement codes mapped to actual flow rates?
    Displacement codes indicate the nominal flow rate in USgpm at 1200 r/min and 0.69 MPa. For exact geometric displacement in mL/r, please refer to the Technical Data table.
    What mounting options are available for the SQP series?
    By default, the pumps are configured for Flange Mounting. If you require Foot Mounting, specify the "F" designator in the model code.
    Can the outlet port positions be adjusted?
    Yes, multiple port positions can be selected (e.g., inline, opposite, 90° or 135° clockwise/counter-clockwise relative to the inlet) depending on the specific SQP series. Consult the Outlet Positions chart for details.
    What is the speed range for these double-stage vane pumps?
    The minimum operating speed for all SQP series pumps is 600 r/min, while the maximum speed depends on the single pump configurations within the series.