Leave Your Message

China Suppliers Factory Durable Denison T67DBB T6DC T67DDBS Series Hydraulic Vane Pump for Heavy Equipment

Introducing the VICKS T6T7 series triple pump, a top-tier solution for hydraulic efficiency and versatility in complex industrial machinery. Manufactured in China, this innovative pump combines three independent sections into a single, compact unit, enabling it to deliver multiple hydraulic power levels from one drive location. Ideal for diverse applications, this product meets varying hydraulic functions with different pressure and flow demands simultaneously. As a reliable option from leading suppliers in the industry, our factory is committed to providing high-quality products that enhance operational performance. Experience unparalleled efficiency with the VICKS T6T7 series triple pump, designed for the demands of modern industrial applications

    Model Representation

    T6DCC (M) -042 -017 -010 -1 R 02 -A 1 01
    Series Type Code Flow-shaft end Pump Flow-mid pump Flow-cover end pump Shaft type Rotation Port positions Design number Sealing Level Port dimensions
    T67DBB (S) NO: industrial type

    M: truck type

    S: truck type use SAE SAE C J744 installation flange
    014/B14, 017/B17, 020/B20, 024/B24, 028/B28, 031/B31, 035/B35, 038/B38, 042/B42, 045/B45, 050/B50, 061 B02, B03, B04, B05, B06, B07, B08, B10, B12, B15, B20 B02, B03, B04, B05, B06, B07, B08, B10, B12, B15, B20 See size of shaft Viewed from shaft end of pump

    R- right hand for clockwise

    L- left hand for counter-clockwise
    see picture below A 1-S1, (Buna) NBR Nitrile rubber

    5-S5, (Viton) Fluororubber
    NO
    T67DCB (S) 014/B14, 017/B17, 020/B20, 024/B24, 028/B28, 031/B31, 035/B35, 038/B38, 042/B42, 045/B45, 050/B50, 061 003/B03, 005/B05, 006/B06, 008/B08, 010/B10, 012/B12, 014/B14, 017/B17, 020/B20, 022/B22, 025/B25, 028/B28, 031/B31 B02, B03, B04, B05, B06, B07, B08, B10, B12, B15, B20 NO
    T6DCC 014/B14, 017/B17, 020/B20, 024/B24, 028/B28, 031/B31, 035/B35, 038/B38, 042/B42, 045/B45, 050/B50, 061 003/B03, 005/B05, 006/B06, 008/B08, 010/B10, 012/B12, 014/B14, 017/B17, 020/B20, 022/B22, 025/B25, 028/B28, 031/B31 003/B03, 005/B05, 006/B06, 008/B08, 010/B10, 012/B12, 014/B14, 017/B17, 020/B20, 022/B22, 025/B25, 028/B28, 031/B31 00、01, See installation dimensions
    T67DDBS 014/B14, 017/B17, 020/B20, 024/B24, 028/B28, 031/B31, 035/B35, 038/B38, 042/B42, 045/B45, 050/B50, 061 014/B14, 017/B17, 020/B20, 024/B24, 028/B28, 031/B31, 035/B35, 038/B38, 042/B42, 045/B45, 050/B50, 061 B02, B03, B04, B05, B06, B07, B08, B10, B12, B15, B20 NO
    T6DDC 014/B14, 017/B17, 020/B20, 024/B24, 028/B28, 031/B31, 035/B35, 038/B38, 042/B42, 045/B45, 050/B50, 061 014/B14, 017/B17, 020/B20, 024/B24, 028/B28, 031/B31, 035/B35, 038/B38, 042/B42, 045/B45, 050/B50, 061 003/B03, 005/B05, 006/B06, 008/B08, 010/B10, 012/B12, 014/B14, 017/B17, 020/B20, 022/B22, 025/B25, 028/B28, 031/B31 00、01, See installation dimensions
    T6EDB (S) 042, 045, 050, 052, 057, 062, 066, 072, 085 014/B14, 017/B17, 020/B20, 024/B24, 028/B28, 031/B31, 035/B35, 038/B38, 042/B42, 045/B45, 050/B50, 061 B02, B03, B04, B05, B06, B07, B08, B10, B12, B15, B20 NO
    T6EDC 042, 045, 050, 052, 057, 062, 066, 072, 085 014/B14, 017/B17, 020/B20, 024/B24, 028/B28, 031/B31, 035/B35, 038/B38, 042/B42, 045/B45, 050/B50, 061 003/B03, 005/B05, 006/B06, 008/B08, 010/B10, 012/B12, 014/B14, 017/B17, 020/B20, 022/B22, 025/B25, 028/B28, 031/B31 00、01, See installation dimensions
    003/B03
    In displacement code, 0 means single steering valve plate structure, B means the two steering valve plate structure.
    The data of relevant series, model are unanimous. Please see T6 series-single pumps data.

    Port positions (Viewed from shaft end of pump)

    T67DBB(S)
    T67DCB(S) T6DCC T67DDBS T6DDC T6EDB(S) T6EDC
    T6T7 Series-treble Pumps detail

    Installation Dimensions

    Durable-Deniso-T6-T7
    T6DCC T67DCB(S) T67DBB(S)
    E 38.1
    F 138.0
    G 404.0
    I 119.3
    J1 J2 127.00
    126.95
    N 181.0
    O 212.4
    ΦP 17.5
    Q 84.4

    Shaft Extension

    Model Shaft code Max torque (N.m) L1 L2 DIA K1xK2 H1 M1
    T67DBB(S) T67DCB(S) T6DCC 1 721 83.6 49.3 31.750/31.700 6.35x6.30 34.6 -
    2 1108 89.7 50.8 38.100/38.075 9.52x9.47 42.4 -
    3 55.2 38.0 SAE J498b 1class,Diametral pitch12/24,14T -
    4 61.0 31.5 SAE J498b 1class,Diametral pitch12/24,17T -
    T6DCC 5 76.0 48.0 SAE J498b 1class,Diametral pitch12/24,14T -

    ●work at maximum flow and pressure.

    Oil port Flange Install Dimensions(mm)
    A1 B1 ΦC1 D1 T1 Thread
    T67DBB(S) T67DCB(S) P1 1-1/4" F10 30.2 58.7 31.8 82.6 7/16"-14UNCx22.3
    P2 1" F08 26.2 52.4 25.4 101.6 3/8"-16UNCx19.0
    P3 3/4" F06 22.2 47.6 19.0 74.7 3/8"-16UNCx19.0
    S 4" F32 77.8 130.2 101.6 127 5/8"-11UNCx30.0
    T6DCC P1 1-1/4" F10 30.2 58.7 31.8 82.6 7/16"-14UNCx22.3
    P2 1" F08 26.2 52.4 25.4 101.6 3/8"-16UNCx19.0
    P3 01:3/4" F06 22.2 47.6 19.0 74.7 3/8"-16UNCx19.0
    P3 00:1" F08 26.2 52.4 25.4 74.7 3/8"-16UNCx19.0
    S 4" F32 77.8 130.2 101.6 127 5/8"-11UNCx30.0
    Durable-Deniso-T6-T72
    T6DDCS T67DDBS
    E 38.1
    F 148.5
    G 455.0
    I 125.0
    J1 J2 127.00
    126.95
    N 181.0
    O 213.0
    ΦP 17.5
    Q 120.0
    Model Shaft code Max torque (N.m) L1 L2 DIA K1xK2 H1 M1
    T67DDBS T6DDCS 1 686 84.0 49.3 31.750/31.700 7.94x7.89 35.27 M10x20
    2 1148 91.0 50.8 38.100/38.075 9.52x9.47 42.36 M10x20
    5 883 84.0 60.0 34.900/34.850 7.94x7.89 38.42 M10x20
    3 971 56.0 38.0 SAE J498b 1class,Diametral pitch 12/24,14T -
    4 62.0 31.5 SAE J498b 1class,Diametral pitch 12/24,17T -

    ●work at maximum flow and pressure.

    Oil port Flange Install Dimensions(mm)
    A1 B1 ΦC1 D1 T1 Thread
    T67DDBS P1 1-1/4" F10 30.2 58.7 31.8 82.6 7/16"-14UNCx22.3
    P2 1-1/4" F10 30.2 58.7 31.8 101.6 7/16"-14UNCx24.0
    P3 3/4" F06 22.2 47.6 19.0 74.7 3/8"-16UNCx19.0
    S 4" F32 77.8 130.2 101.6 115.0 5/8"-11UNCx30.0
    T6DDCS P1 1-1/4" F10 30.2 58.7 31.8 82.6 7/16"-14UNCx22.3
    P2 1-1/4" F10 30.2 58.7 31.8 101.6 7/16"-14UNCx24.0
    P3 01:3/4" F06 22.2 47.6 19.0 74.7 3/8"-16UNCx19.0
    P3 00:1" F08 26.2 52.4 25.4 74.7 3/8"-16UNCx19.0
    S 4" F32 77.8 130.2 101.6 115.0 5/8"-11UNCx30.0
    Durable-Deniso-T6-T73
    T6EDC T7EEC
    E 42.9 E 42.9
    F 133.3 F 167.3
    G 468.0 G 516.8
    I 148.4 I 162.2
    J1 J2 250h8 J1 J2 250h8
    ΦN 315.0 ΦN 315.0
    O 273.0 O 273.0
    ΦP 22.0 ΦP 22.0
    Q 120.0 Q 120.0
    T6EDCS T67EDB(S) T7EECS
    E 42.9 E 42.9
    F 133.3 F 167.3
    G 468.0 G 516.8
    I 148.4 I 162.2
    J1 J2 165.10
    165.05
    J1 J2 165.10
    165.05
    ΦN 315.0 ΦN 317.5
    O 273.0 O 273.0
    ΦP 20.8 ΦP 20.8
    Q 120.0 Q 120.0
    Model Shaft code Max torque (N.m) L1 L2 DIA K1xK2 H1 M1
    T67EDBS, T6EDC T6EDCS 1 92.0 63.0 45h7 14h7x9 48.5 M12x24
    T6EDCS 2 100.0 63.5 44.45/44.40 11.11x11.06 49.3 1/2-UNCx24
    3 75.0 48.8 SAE J498b 1class, Diametral pitch8/16, 13T -
    T7EEC(S) 2 92.0 63.0 45h7 14h7x9 48.5 M12x24

    work at maximum flow and pressure

    Oil port Flange Install Dimensions(mm)
    A1 B1 ΦC1 D1 T1 Thread
    T67EDBS P1 1-1/2" F12 35.7 69.9 37.1 139.7 1/2"-13UNCx30.0
    P2 1-1/4" F10 30.2 58.7 31.8 101.6 7/16"-14UNCx24.0
    P3 3/4" F06 22.2 47.6 19.0 74.7 3/8"-16UNCx19.0
    S 4" F32 77.8 130.2 101.6 115.0 5/8"-11UNCx30.0
    T6EDC T6EDCS P1 1-1/2" F12 35.7 69.9 37.1 139.7 1/2"-13UNCx30.0
    P2 1-1/4" F10 30.2 58.7 31.8 101.6 7/16"-14UNCx24.0
    P3 01:3/4" F06 22.2 47.6 19.0 74.7 3/8"-16UNCx19.0
    P3 00:1" F08 26.2 52.4 25.4 74.7 3/8"-16UNCx19.0
    S 4" F32 77.8 130.2 101.6 115.0 5/8"-11UNCx30.0
    T7EEC(S) P1 1-1/2" F12 35.7 69.9 37.1 139.7 M12x30
    P2 1-1/2" F12 35.7 69.9 37.1 98.6 M12x30
    P3 1" F08 26.2 52.4 25.4 74.7 M10x19
    S 4" F32 77.8 130.2 101.6 115.0 M16x30

    Frequently Asked Questions (FAQ)

    1. What do the displacement codes '0' and 'B' signify in the T6/T7 series vane pumps?
    In the displacement code, '0' represents a single steering valve plate structure, whereas 'B' indicates a double steering valve plate structure.
    2. How are the pump's rotation directions designated in the model number?
    The rotation is determined by viewing the pump from its shaft end: 'R' indicates right-hand rotation (clockwise), and 'L' indicates left-hand rotation (counter-clockwise).
    3. What is the difference between sealing levels '1' and '5'?
    Sealing level '1' corresponds to NBR (Buna) Nitrile rubber seals, suited for standard applications. Sealing level '5' designates Viton (Fluororubber) seals, which offer enhanced thermal and chemical resistance.
    4. What do the type codes 'M' and 'S' mean?
    The type code indicates the application category: 'M' is used for truck type applications, and 'S' is used for truck types fitted with an SAE C J744 installation flange. If left blank, it indicates a standard industrial type.
    5. Where can I find the precise installation measurements for my specific pump model?
    The installation measurements, including parameters like E, F, G, I, and port sizes, are detailed in the dimensional tables categorized by pump model groupings (e.g., T6DCC, T6DDCS, T6EDC).
    6. Can these vane pumps operate continuously at maximum flow and pressure?
    Shaft options marked with a dot (●) in the technical tables are specifically rated to work reliably at maximum flow and pressure limits. Always verify the maximum torque limits for your selected shaft code.

    Leave Your Message